John Lewis JLBIGGH756 Manual de usuario Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Replacement of the
connection cable
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel with similar
competencies, in accordance with
the current regulations.
To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that the
cable section is applicable to the
voltage load and the working
temperature. The yellow/green
earth wire (B) must be
approximately 2 cm longer than the
live and neutral wire (A).
A B
1. Connect the green and yellow (earth) wire to
the terminal which is marked with the letter 'E',
or the earth symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 450 mm
30 mm
A) supplied seal
B) supplied brackets
Caution! Install the appliance
only on a worktop with flat
surface.
Possibilities for insertion
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
Kitchen unit with door
A) Removable panel
B) Space for connections
Hob User Manual
19
Vista de pagina 18