John Lewis JLFSMC613 Manual de usuario Pagina 36

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 35
Warning! Before gas connection
disconnect the mains plug from
the mains socket or switch off
the fuse in the fuse box. Close
the primary valve of the gas
supply.
Supply piping should not be less than
R3/8. Connection is made to the Rc
½ (1/2 “ B.S.P.) female threaded.
Entry pipe located just below the hob
level on the rear left hand side of the
appliance.
The gas supply ramp is on the rear side
of the appliance.
Warning! Only liquid sealants to
be used when inlet gas pipe is
fitted i.e.: do not use P.T.F.E.
sealant tape.
When installation is complete.
Carry out a gas tightness test
and make sure that the seal of
each pipe fitting is correct.
Important! Use flexible tubing, which
comply with BS.669 current edition.
A
B
C
C
D
E
Warning! The gas bayonet must
be in mark area.
Dimension mm
A250
B680
C50
D250
E580
Pressure test
The Rapid injector is used as a pressure test
point.
1. Connect the pressure gauge to the Rapid
injector.
2. Examine the supply pressure by turning the
Rapid burner and one other burner fully on,
and lighting them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work correctly.
Checking the hob burners
1. Lift the lid.
2. Put in the burner crowns and caps. Make
sure that they are correctly seated.
3. Put in the pan supports.
4. Check each of the burners in turn by turning
the burner control knob to the symbol
.
5. Release the knob when the burners come
on.
Checking the lid shut-off device
1. Lift the lid.
36 Cooker user manual
Vista de pagina 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 42 43 44

Comentarios a estos manuales

Sin comentarios