John Lewis JLBIGGH704 Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
12
Minimum flame adjustmentMinimum flame adjustment
Minimum flame adjustmentMinimum flame adjustment
Minimum flame adjustment
If it is necessary to adjust the minimum flame setting, proceed
as follows:
1. Carry out the steps described in the paragraph “Setting
the hob for the new gas type” - points 1, 2, 3, 4 and 5.
2. Light the burner to be adjusted by touching the Burner
Ignition Control
.
The burner lights at the maximum flame level and, after a
regular flame is obtained, it sets at the minimum flame
level .
3. If the minimum level is too low or not satisfactory to
maintain the burner lit, touch the Increasing
or
Decreasing
Control to carry out a fine adjustment
(visual check).
4. Switch off the hob touching the main ON/OFF
Control
.